Flow Meters – Silver Automation Instruments

1. Wiring diagram of ultrasonic flowmeter

Ultrasonic flowmeter wiring is mainly divided into two parts: host wiring and probe wiring. There are differences between different brands and models, and it is necessary to follow the product manual for accuracy. 1. Power input for host wiring: Supports AC 220V or DC 24V power supply. Choose one of them according to the wiring diagram. Sensor interface: - Downstream probe connected

1.

2. Terminal 3 (GND, DN -, DN+), usually only need to be connected to DN - and DN+(terminals 2 and 3) - Upstream probe connected

4.

5. Terminal 6 (GND, UP -, UP+), usually only need to be connected to UP - and UP+(terminals 5 and 6) 4-20mA output: AO terminal connected to signal positive pole, 24V - terminal connected to signal negative pole 485 communication: connect 485 OUT A and 485 OUT B terminals Heat meter function: - Water supply terminal connected to TX

1. T

1. GND - Return terminal TX

2. T

2. GND (supply and return GND are connected together) Relay output: Connect RELAY+and RELAY - terminals 2. Probe wiring Probe cables usually include shielded wires, signal positive (+) and signal negative (-) terminals. Conventional connections only require connecting the+and - terminals, and shielded wires can be omitted. Due to possible differences in terminal definitions and wiring methods among different manufacturers, please make sure to check the wiring diagram provided in the instruction manual before actual wiring.

2. Is there a requirement for the insertion depth when installing the Cologne ultrasonic flowmeter?

There are clear requirements for the insertion depth of the probe when installing the Cologne ultrasonic flowmeter, and it must be strictly operated according to the specifications. 1 The determination of insertion depth is mainly determined by the diameter of the pipeline, and the larger the diameter, the deeper the insertion depth. Small pipe diameters (such as below DN100) are usually inserted by a few centimeters, while large pipe diameters (such as above DN1000) may need to be inserted by more than ten centimeters or even deeper.

2. Core installation requires that the probe must reach a stable flow velocity area near the center of the pipeline to ensure that the average fluid flow velocity is captured. Insertion too shallow or too deep can cause measurement errors and even damage to the sensor. 3. Specific operating specifications vary depending on the insertion depth of different models, and the installation manual provided by the manufacturer must be strictly followed. Cologne will provide specific insertion depth values, calculation formulas, or installation positioning templates for each model. Special tools should be used for accurate positioning during installation, and signal strength and quality indicators should be used to verify whether the installation position is qualified after installation.

3. What are the top ten flowmeter manufacturers?

According to the industry information updated on February 9, 2026, the list of the top ten flowmeter manufacturers is as follows:

1. Emerson belongs to Emerson Electric (China) Investment Co., Ltd., which has top-notch technology in the fields of oil and gas trade handover and multiphase flow measurement. Its products meet the highest international standards and are suitable for high demand scenarios such as oil and gas extraction, transportation, and