About detail
About UsCurrent position >About Us

Company Profile

Turbine Flow Meters: High-Speed Volumetric Tracking for Low-Viscosity Fluids

Quick Answer

Turbine flow meters from Silver Automation Instruments track low-viscosity liquids from 0.08 to 800 m3/h with a repeatability of ±0.1 percent. These meters fit clean fluids in the 1 to 100 cP range including diesel, light oils, water, solvents, and LPG. Send us your flow range, pipe size, and viscosity to get a specific model and quote.

Why Turbine Meters Work Well for Low-Viscosity Fluids

A turbine flow meter uses a free-spinning rotor placed directly in the flow path. The rotor speed follows the linear velocity of the fluid. Low-viscosity fluids let the rotor spin freely without thick boundary layers. This gives fast response and high repeatability on clean liquids.

In practice, most engineers choose a turbine meter for custody transfer, batching, or fuel tracking. The reason is simple. A well-built turbine meter offers turndown ratios up to 10:1 or 15:1 on low-viscosity liquids. You do not need a long upstream run when the flow profile is stable.

Keep one thing in mind. Turbine meters are not ideal for dirty fluids or liquids above 100 cP. For those cases, a positive displacement meter like an oval gear flow meter may be a better fit.

Specific Applications We See on Customer Sites

We ship turbine flow meters to Southeast Asia, Oceania, Latin America, the Middle East, and Africa. The fluids vary. But the problems are similar. Customers need a compact meter that tracks volume without shutting down the line.

A fuel distributor in Vietnam requested a DN50 turbine flow meter for diesel loading at 200 L/min. The meter included a 4-20 mA HART output and a local totalizer. The customer wanted a pulse output for batch control. We supplied the preconfigured unit in two weeks.

A water treatment plant in the Philippines needed DN100 turbine meters for filtered water distribution. The plant runs at 80 m3/h and 4 bar. Because the water is clean, the turbine meter works with a strainer and straight pipe sections.

Last year, a chemical batch plant in Indonesia asked for DN25 turbine meters for solvent dosing. The fluid was ethyl acetate at 0.45 cP. The fast rotor response helped the PLC shorten each batch time by 8 seconds. This reduced solvent waste and improved line throughput.

Common Specifications We Quote

Most requests from OEMs and distributors include pipe size, flow range, output signal, and process connection. The standard factory range is called STF inside our plant. DN15, DN25, DN40, DN50, DN80, and DN100 are the most stocked sizes.

DN15 to DN200 line sizes cover small pilot plants up to large water or fuel pipelines. Flow ranges start at 0.08 m3/h and reach 800 m3/h depending on line size. Accuracy is often ±0.5 percent of reading for standard models. Repeatability is ±0.1 percent.

Outputs include pulse, 4-20 mA with HART, and local digital totalization. For hazardous areas, we offer ATEX Zone 1 and Zone 2 certified models. Process connections include flanged, threaded, and tri-clamp for hygienic lines. Wetted parts are usually 316 stainless steel or anodized aluminum for certain fuel meters.

Temperature and pressure ratings matter. Standard units handle -20 to 120 °C and up to 100 bar. We ask customers for their minimum and maximum flow rates. This prevents oversizing and keeps the rotor in its linear range.

How to Specify a Turbine Flow Meter for Diesel, Water, or Solvent

Do not start with just a price request. Send four data points. Flow range in L/min or m3/h. Pipe size in DN. Viscosity in cP. Output signal.

For diesel, we need your minimum and maximum delivery rate. Water requires pipe size and operating pressure. For solvents, send the chemical name or viscosity range. We check material compatibility before quoting.

Because a turbine meter is a velocity device, straight run requir